  • You’re explaining scenarios where you incorrectly use my setup.

    You can wire the switches so that if switched off it only kills power to that server and nothing else in the chain. You then basically have this, but modular:
    image

    Yea if you rip out a cord that you shouldn’t you’re going to lose power, that is true of any power strip.

    This has more components, so more things can fail, I will give you that, but that’s unlikely and for me at least, worth the trade off in making it modular.

    If the above picture was powering your servers, and you wanted to add a 7th plug, you’d have to unplug everything and buy a power adapter with more sockets, and deal with the rats nest of cables that follows, or add another of these that might have the same problem in the future.
















  • Yea each one runs through the previous module, so all the power goes through the first module.

    IEC 13/14 connectors are rated for 10A (2300 W at 230 V) which isn’t much lower than what you can run through your wall outlet. And in reality they can probably handle 15A(What your wall can handle) as they are commonly refereed to as “Kettle cords” and used by kettles which draw ~13 Amps.

    That’s very high, to give you an idea the 6 things I have plugged in draws ~240w, so I could chain up ~60 mini PC’s and only then would I be over the ~2300w limit.

    I do now mention this in the Safety section of my “How to build this” write up


  • Thanks yea I made sure to add this Safety section to my write-up on how to build this yourself, and I reference back to it a lot, so it’s painfully clear.

    I printed this in PETG which can take the heat easily, but ideally you use UL 94 V-0 which is also flame retardant.

    I did make sure everything is very well insulated, and pulled hard on every connection to make sure it’s held down properly.

    **Safety**  
    
    This part carries live mains. Mains wiring kills people who get it wrong, and a fault in a printed enclosure can start a fire.  
    
    Do not build it unless you are competent to wire mains and permitted to do so where you live. Sleeve or shroud all live terminals. PLA softens around 60 °C, PETG around 80 °C. Neither is flame retardant. Only a UL 94 V-0 filament is.  
    
    Wire the protective earth if anything you plug in needs it.  
    
    Build it at your own risk. I take no responsibility for injury, death, fire, or damage resulting from anything in this repository.